MGate MB3170I-M-SC-T

 

MGate MB3170I-M-SC-T


Was 723.50 Save 6% 680.09  Ex VAT Was 904.38 Save 6% 850.11  Inc VAT

PRE-ORDER

- +

This product is currently out of stock. Your item will be shipped when it is back in stock.


DELIVERY CUTOFF TIME REMAINING:

- - : - - : - -

 

Industrial 1-Port Modbus Gateway with Multi-Mode Fiber and Wide Temperature Range

Optimize your industrial automation network with this advanced 1-port Modbus gateway, engineered for reliable and flexible Modbus TCP and Modbus RTU/ASCII communication. Featuring a 100BaseFX multi-mode fiber port with SC connectors and built-in 2 kV optical isolation, this gateway ensures robust data transmission in the harshest environments from -40 to 75°C.

High-Performance Industrial Communication

Designed for complex industrial applications, this Modbus gateway supports seamless protocol conversions between Modbus TCP and Modbus RTU/ASCII, simplifying network integration and enhancing system efficiency.

Key Features

  • 1-port Modbus gateway with 100BaseFX multi-mode fiber (SC connectors)
  • 2 kV isolation protection for enhanced reliability and safety (on "-I" models)
  • Wide operating temperature range from -40 to 75°C for extreme industrial environments
  • Auto Device Routing for easy and intuitive configuration
  • Supports routing by TCP port or IP address for flexible deployment options
  • Connects up to 32 Modbus TCP servers and up to 31 or 62 Modbus RTU/ASCII slaves
  • Accessed by up to 32 Modbus TCP clients with 32 Modbus request retention per master
  • Supports Modbus serial master to Modbus serial slave communication
  • Built-in Ethernet cascading for simplified wiring and installation
  • Supports both 10/100BaseTX (RJ45) and 100BaseFX fiber connections
  • Emergency request tunnels for Quality of Service (QoS) control
  • Embedded Modbus traffic monitoring simplifies diagnostics and troubleshooting
  • Redundant dual DC power inputs and integrated relay output for fail-safe operations

Reliable Fiber Communication in Demanding Applications

Ideal for industries such as manufacturing, oil and gas, transportation, and utilities, this advanced Modbus gateway offers a secure and efficient fiber-optic interface, supporting longer transmission distances and immunity to electrical noise.

Upgrade your Modbus networking with this industrial-grade gateway and experience seamless data flow, enhanced integration, and operational stability across your systems.

Ethernet Interface
  • 10/100BaseT(X) Ports (RJ45 connector)

    • 2 (1 IP, Ethernet cascade)
      Auto MDI/MDI-X connection
  • Magnetic Isolation Protection

    • 1.5 kV (built-in)
  • Optical Fiber

Ethernet Software Features
  • Industrial Protocols

    • Modbus TCP Client (Master)
      Modbus TCP Server (Slave)
  • Configuration Options

    • Web Console (HTTP/HTTPS)
      Device Search Utility (DSU)
      MGate Manager
      MCC Tool
      Telnet Console
  • Management

    • ARP
      DHCP Client
      DNS
      HTTP
      HTTPS
      SMTP
      SNMP Trap
      SNMPv1/v2c/v3
      TCP/IP
      Telnet
      UDP
      NTP Client
  • MIB

    • RFC1213, RFC1317
  • Time Management

    • NTP Client
Security Functions
  • Authentication

    • Local database
  • Encryption

    • HTTPS
      AES-128
      AES-256
      SHA-256
  • Security Protocols

    • SNMPv3
      HTTPS (TLS 1.2)
Serial Interface
  • No. of Ports

    • 1
  • Connector

    • DB9 male for RS-232 and terminal block for RS-422/485
  • Serial Standards

    • RS-232/422/485 (software selectable)
  • Baudrate

    • 50 bps to 921.6 kbps
  • Data Bits

    • 7, 8
  • Parity

    • None
      Even
      Odd
      Space
      Mark
  • Stop Bits

    • 1, 2
  • Flow Control

    • DTR/DSR
      RTS Toggle (RS-232 only)
      RTS/CTS
  • Pull High/Low Resistor for RS-485

    • 1 kilo-ohm, 150 kilo-ohms
  • Terminator for RS-485

    • 120 ohms
  • Isolation

    • 2 kV
  • RS-485 Data Direction Control

    • ADDC (automatic data direction control)
Serial Signals
  • RS-232

    • TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
  • RS-422

    • Tx+, Tx-, Rx+, Rx-, GND
  • RS-485-2w

    • Data+, Data-, GND
  • RS-485-4w

    • Tx+, Tx-, Rx+, Rx-, GND
Serial Software Features
  • Industrial Protocols

    • Modbus RTU/ASCII Master
      Modbus RTU/ASCII Slave
Modbus (Transparent)
  • Max. No. of Client Connections

    • 32
  • Max. No. of Server Connections

    • 32
Power Parameters
  • Input Voltage

    • 12 to 48 VDC
  • Input Current

    • 555 mA @ 12 VDC
  • Power Connector

    • 7-pin terminal block
Relays
  • Contact Current Rating

    • Resistive load: 1 A @ 30 VDC
Physical Characteristics
  • Housing

    • Plastic
  • IP Rating

    • IP30
  • Dimensions (with ears)

    • 29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)
  • Dimensions (without ears)

    • 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)
  • Weight

    • 360 g (0.79 lb)
Environmental Limits
  • Operating Temperature

    • -40 to 75°C (-40 to 167°F)
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
Standards and Certifications
  • EMC

    • EN 55032/35
  • EMI

    • CISPR 32, FCC Part 15B Class A
  • EMS

    • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
      IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
      IEC 61000-4-5 Surge: Power: 2 kV
      IEC 61000-4-6 CS: 10 V
      IEC 61000-4-8 PFMF
      IEC 61000-4-11
  • Hazardous Locations

    • ATEX
      Class I Division 2
      IECEx
  • Maritime

    • DNV
  • Freefall

    • IEC 60068-2-32
  • Shock

    • IEC 60068-2-27
  • Vibration

    • IEC 60068-2-6
      IEC 60068-2-64
  • Safety

    • UL 60950-1
      IEC 60950-1
      EN 62368-1
      UL 508
MTBF
  • Time

    • 1,385,414 hrs
  • Standards

    • Telcordia SR332
Warranty