85M-6810-T

 

85M-6810-T


Was kr5,972.45 Save 6% kr5,614.10  Ex VAT Was kr7,465.60 Save 6% kr7,017.65  Inc VAT

PRE-ORDER

- +

This product is currently out of stock. Your item will be shipped when it is back in stock.


DELIVERY CUTOFF TIME REMAINING:

- - : - - : - -

Lead Time: 8~12W

 

Rugged Industrial I/O Expansion Module for ioPAC 8500/8600 Series

Enhance your industrial automation systems with this rugged I/O expansion module designed specifically for the ioPAC 8500 and ioPAC 8600 Series. Engineered to thrive in harsh environments, this high-performance module extends your system’s communication and input/output capabilities while meeting stringent railway and industrial standards.

Designed for Harsh Industrial and Railway Environments

Meeting key portions of the EN 50155 standard and fully compliant with EN 50121-3-2 and EN 50121-4 specifications, this module is built to support mission-critical applications in railway, transportation, and heavy industrial settings.

Key Features and Benefits

  • Wide operating temperature range from -40 to 75°C (-40 to 167°F) for extreme conditions
  • Compact and durable design allows for deployment in space-constrained or rugged environments
  • Millisecond timestamp granularity ensures precise logging for digital and analog inputs
  • Supports high-speed analog input sampling rates up to 40 kHz
  • Pre-recorded analog input data logging enhances historical analysis and troubleshooting
  • Up to 4 flexible serial ports supporting RS-232/422/485 communication for maximum versatility
  • Easy expansion of I/O and communication capabilities for ioPAC 8500/8600 modules

Reliable Thermocouple Monitoring

This module supports up to 8 thermocouple (TC) channels, making it ideal for temperature monitoring in automation systems that require accurate and reliable data acquisition across a wide temperature range.

Ideal for:

  • Industrial automation and control systems
  • Railway onboard and wayside monitoring
  • Remote data acquisition in harsh environments
  • Applications requiring precise analog input and timestamp accuracy

Upgrade your ioPAC system with this reliable I/O expansion module and ensure high-performance data acquisition and robust field connectivity — even in the most demanding industrial conditions.

Input/Output Interface
  • Isolation

    • 3k VDC or 2k Vrms
  • Thermocouple Channels

    • 8
Digital Outputs
  • Pulse Output Frequency

    • 5 kHz
Thermocouples
  • Millivolt Accuracy

    • ±0.1% FSR @ 25°C
      ±0.3% FSR @ -40 to 75°C
  • Connector

    • Spring-type Euroblock terminal
  • Input Impedance

    • 1 mega-ohms (min.)
  • Millivolt Type

    • ±19.532 mV
      ±39.062 mV
      ±78.126 mV
      Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30 VDC (power on)
  • Resolution

    • 16 bits
  • Sampling Rate

    • All channels: 12 samples/sec
      Per channel: 1.5 samples/sec
  • Sensor Type

    • J, K, T, E, R, S, B, N
Power Parameters
  • Power Consumption

    • 24.1 mA @ 24 VDC
Physical Characteristics
  • Dimensions

    • 25 x 128.2 x 85.5 mm (0.98 x 5.05 x 3.37 in)
  • Weight

    • Under 80 g
  • Wiring

    • I/O cable, 14 to 28 AWG
Environmental Limits
  • Operating Temperature

    • -40 to 75°C (-40 to 167°F)
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
  • Altitude

    • 2000 m
      Note: Please contact Moxa if you require products guaranteed to function properly at higher altitudes.
Standards and Certifications
  • EMC

    • EN 55032/24
      EN 61000-6-2/-6-4
  • EMI

    • CISPR 32, FCC Part 15B Class A
  • EMS

    • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
      IEC 61000-4-3 RS: 5100 MHz to 6000 MHz: 3 V/m
      IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
      IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
      IEC 61000-4-6 CS: 10 V
      IEC 61000-4-8 PFMF
  • Railway

    • EN 50121-4
      EN 50155 (complies with a portion of EN 50155 specifications)
  • Safety

    • UL 508
  • Shock

    • IEC 60068-2-27
  • Vibration

    • IEC 60068-2-6
MTBF
  • Time

    • 2,324,891 hrs
  • Standards

    • Telcordia SR332
Warranty